Aircel Air-Cooled & Water-Cooled Aftercoolers

Aircel Air-Cooled & Water-Cooled Aftercoolers

$0.00
Air-Cooled 130 scfm - 4,500 scfm Water-Cooled 50 scfm - 3,000 scfm

Aircel Combo Featured

With expertise in compressed air filtration and separation technologies, Aircel offers a complete line of highly efficient air-cooled and water-cooled aftercoolers providing an economical way to remove water vapor and cool compressed air to useable levels preparing for further filtration and drying applications.

Aircel Air-Cooled Aftercoolers provide economical cooling by utilizing ambient air to cool the hot compressed air from an air compressor. Discharge air from an air compressor is generally 180°F - 350°F, depending on the type of compressor. With a properly sized aftercooler, as much as 60% of the water in compressed air can be removed.

Aircel Water-Cooled Aftercoolers and separators are an ideal combination to remove troublesome moisture from compressed air. With proper installation of aftercoolers and matching liquid separators, it has shown that they perform effectively in maintaining trouble-free operation of compressed air equipment. By lowering the temperature of the compressed air in downstream air lines using water-cooled aftercoolers, up to 70% of the water vapor present condenses to a liquid, which can then be removed by moisture separators.

Learn more about aftercoolers and how they work with your compressed air system. If you have questions about how to find a aftercooler to fit your air compressor, call our knowledgeable customer service team toll-free: 866-650-1937.

Search below by air-cooled and water-cooled models to find more information on specific models, pricing, and information. Download the brochure to learn more about the Aircel Aftercoolers.

 

 

Air-Cooled Models

Dimensions & Specifications

Search below based on your specific needs and click on a model to order, view pricing, or download product information. If you have questions call our customer service toll-free: 866-650-1937.

Electric Motor Option Standard Optional
Model Number HP RPM Motor Frame Voltage Full Load Amps 230V Voltage Full Load Amps 230V Matching Water Separator
CAA-130 1/3 3450 IEC 63 115/208/230-1-60 2.6 230/460-3-60 1.2 A108WS
CAA-225 1/2 3450 IEC 71 115/208/230-1-60 3.4 230/460-3-60 2.0 A128WS
CAA-450 1/2 1725 NEMA 56C 230/460-3-60 4.4 115/208/230-1-60 2.0 A208WS
CAA-800 1 1725 NEMA 56C 230/460-3-60 6.4 115/208/230-1-60 3.8 A254WS
CAA-1400 2 1725 NEMA 56C 230/460-3-60 10 115/208/230-1-60 6.2 A340WS
CAA-2000 5 1725 NEMA 184TC 230/460-3-60 13.4 N/A N/A CF
CAA-3000 7.5 1725 NEMA 213TC 230/460-3-60 19.6 N/A N/A CF
CAA-3500 7.5 1725 NEMA 213TC 230/460-3-60 19.6 N/A N/A CF
CAA-4500 10 1725 NEMA 213TC 230/460-3-60 26.0 N/A N/A CF

*Contact us toll-free: 866-650-1937 for details and pricing on LS separator models.

Aircel offers an Air Motor option for Air-Cooled Aftercoolers. Search below based on your specific needs and call our customer service toll-free: 866-650-1937 for more information on pricing.

Air pressure to motor MUST be regulated and lubricated. DO NOT EXCEED fan RPM listed above. Mufflers are included with all motors.

Air Motor Option
Model Number Air Pressure to Motor (PSI) Motor Air Consumption (scfm) Air Motor (NPT) Fan RPM
CAA-130 30 70 1/4" 3450
CAA-225 60 17 1/4" 3450
CAA-450 40 25 1/4" 1725
CAA-800 40 25 1/4" 1725
CAA-1400 50 70 1/2" 1725
CAA-2000 60 150 1-1/4" 1725
CAA-3000 80 200 1-1/4" 1725
CAA-3500 80 200 1-1/4" 1725
CAA-4500 100 240 1-1/4" 1725

Aircel Air-Cooled Aftercoolers provide economical cooling by utilizing ambient air to cool the hot compressed air from an air compressor. Discharge air from an air compressor is generally 180°F - 350°F, depending on the type of compressor. With a properly sized aftercooler, as much as 60% of the water in compressed air can be removed. Air-cooled aftercoolers can reduce the size of a dryer necessary to meet system output air requirements, will extend the life of the dryer and filters, and reduce maintenance, making it an outstanding value! Air-cooled aftercoolers can be sized to cool the hot compressed air within 5°F to 20°F of the ambient air temperature. Aftercoolers can be installed so normal wasted heat can be reclaimed and recirculated.

Features & Benefits

• Advanced technology designs to maximize heat transfer with minimum pressure drop.
• Compact design compared to conventional fan and tube designs provides smaller footprint.
• Corrosion resistance construction.
• Size from 130 to 4500 scfm (at 200°F inlet and 20°F approach).
• Durable aluminum plate core design saves space and minimizes energy usage.
• Horizontal airflow standard with vertical airflow optional.
• Standard TEFC (Totally Enclosed Fan Cooled Motor) for outside applications.

Specifications

Construction
• Cooler Material: Aluminum
• Shroud: Powder Painted Steel
• Fan Guard: Zinc Plated Steel
• Fan Blade: Polypropylene Blades, Aluminum Hub-Balanced for Free Vibration
• Mounting Brackets: Powder Painted Steel
• Matching Water Separators for Aftercoolers Available

Ratings
• Maximum Working Pressure: 250 psig
• Maximum Working Temperature: 250°F

Dimensions

Air-Cooled-Dimensions

Capacity (scfm) Dimensions (inches)
Model Number Rotary 200°F Inlet 2-Stage 250°F Inlet 1-Stage 300°F Inlet A B C Approx. D E F G H (NPT) J K L M Shipping Weight (lbs.)
CAA-130 130 96 80 12.64 15.94 14.72 10.86 2.52 0.75 1.18 1.00 14.65 3.94 3.50 8.19 40
CAA-225 225 175 145 16.30 19.88 15.59 14.53 2.52 0.75 1.77 1.50 18.66 3.94 3.50 8.19 60
CAA-450 450 350 300 21.00 26.38 17.75 18.81 3.15 1.00 1.77 2.00 25.19 4.92 4.53 10.98 137
CAA-800 800 600 500 23.19 30.31 18.74 21.02 3.15 1.00 1.77 2.00 29.13 4.92 4.53 10.98 163
CAA-1400 1,400 1,000 900 27.72 37.00 22.60 25.23 4.33 1.85 1.77 2.50 37.80 5.91 7.87 16.00 240
CAA-2000 2,000 1,600 1,400 35.90 40.94 24.76 30.83 4.33 1.85 1.77 3.00 37.80 5.91 7.87 16.00 350
CAA-3000 3,000 2,400 2,100 37.44 42.91 29.84 30.55 10.91 2.08 1.77 4.00 43.62 5.39 7.87 15.47 380
CAA-3500 3,500 2,900 2,500 44.25 48.82 30.28 34.25 11.57 1.57 1.77 4.00 49.29 5.39 7.87 15.47 505
CAA-4500 4,500 3,500 3,000 57.87 52.76 33.82 43.98 17.56 3.35 2.00 4.00 50.55 7.80 10.00 20.00 645
Water-Cooled Models

Dimensions & Specifications

Search below based on your specific needs and click on a model to order, view pricing, or download product information. If you have questions call our customer service toll-free: 866-650-1937.

    Capacity
(scfm)
Dimensions
(inches)
Connections
(NPT)
 
Model
Number
Design Rotary
200°F
Inlet
2-Stage
250°F
Inlet
Diameter Length Weight (lbs.) Water Air Matching
Separator Model
WA-50 Single Pass 50 40 3.65 13.5 23 1.0 1.5 A058WS
WA-100 Single Pass 100 90 3.65 31.5 33 1.0 1.5 A078WS
WA-150 Single Pass 150 135 5 23.6 54 1.5 2.0 A108WS
WA-250 Single Pass 250 225 5 32.6 76 1.5 2.0 A128WS
WA-300 Single Pass 300 270 5 41.6 82 1.5 2.0 A158WS
WA-400 Single Pass 400 330 6 33.25 98 2.0 3.0 A159WS
WA-600 Single Pass 600 480 6 42.12 115 2.0 3.0 A208WS
WA-800 Single Pass 800 650 6 51.12 130 2.0 3.0 A254WS
WA-1000 Single Pass 1,000 850 6 60.25 150 2.0 3.0 A340WS
WA-1500 Single Pass 1,500 1,250 6 69.25 170 2.0 3.0 A340WS
WA-2000 Single Pass 2,000 1,800 6 78.12 190 2.0 3.0 C/F*
WA-3000 Single Pass 3,000 2,800 8 98.62 390 3.0 4.0 C/F*

*Contact us toll-free: 866-650-1937 for details and pricing on the matching water separator LS models.

Aircel Water-Cooled Aftercoolers and separators are an ideal combination to remove troublesome moisture from compressed air. With proper installation of aftercoolers and matching liquid separators, it has shown that they perform effectively in maintaining trouble-free operation of compressed air equipment. By lowering the temperature of the compressed air in downstream air lines using water-cooled aftercoolers, up to 70% of the water vapor present condenses to a liquid, which can then be removed by moisture separators.

Features & Benefits

• Single pass design with smooth surface copper tubes minimizes fouling and allows lower pressure drop. Two-pass designs are available, contact customer service for more information.
• Counter-flow shell and tube design provides close approach temperature; gains maximum heat removal benefit from expensive cooling water.
• Cooper heat exchanger surfaces provide excellent heat transfer rate.
• Seamless shells have maximum rupture strength and corrosion resistance.
• Tube rolled into tubesheet eliminates thermal stress.
• Removable end bonnets facilitate cleaning and servicing.
• Drain ports on shell side for easy maintenance.
• Compact package provides smaller footprint.
• Can be mounted in horizontal or vertical positions.

More Information

Aircel CAA / WA Aftercoolers Series

Brochure (pdf)

Contact our customer service team by calling toll-free 866-650-1937 or email sales@ecompressedair.com for more information about the Aircel Aftercooler or for customized options and quotes.