Skip Navigation

Aircel HRE Series

Heated Desiccant Air Dryers with Blower -40°F Dew Point (600-10000 scfm)

ECA Best Choice Icon ECA Factory Direct Pricing Icon ECA Request Quote Icon Air Dryer Live Chat IconDryer Sizing Tool

Regenerative compressed air dryers use desiccant to adsorb water vapor from the compressed airstream. In the twin tower design one tower dries the air from the compressor while the desiccant in the other tower is being regenerated to provide continuous operation. These dryers are typically referred to as "heatless" or "heated". Heatless dryers do not use any source of heat for regeneration other than the heat given off during the drying phase. This is known as the "Heat of Adsorption". Heated dryers, on the other hand, utilize an external heat source for regeneration and require little or no process air.

The Aircel HRE Series Dryers (600 - 10,000 scfm) utilize externally heated atmospheric air for regeneration of the desiccant bed. This significantly reduces the use of compressed purge air for regeneration resulting in an overall reduction in the cost of operation. Process air is only consumed during depressurization of the offline tower and during cool-down of the regenerating bed. This amounts to an average process air use of 2% of the rated capacity of the dryer.

• 40°F Dew Point Standard (Contact Us for -100°F)
• Ambient Air Temperature 38°F - 125°F
• Inlet Air Temperature 40°F - 110°F
• Operating Pressure: 60 - 150 psig
• 1 Year Standard Limited Warranty

Pricing includes mounted prefilter and afterfilter, ASME code stamped filter housing, differential pressure gauge, automatic drain valve and initial filter element. If you have questions on how to properly select a compressed air dryer, contact our knowledgeable customer service toll-free: 866-650-1937 or send us an email request.

HRE Overview
Product Selection

Dimensions & Specifications

Search below based on your specific needs and click on a model to order, view pricing, or download product information. If you have questions on how to properly select a compressed air dryer, contact our knowledgeable customer service toll-free: 866-650-1937 or send us an email request. Pricing includes mounted prefilter and afterfilter, ASME code stamped filter housing, differential pressure gauge, automatic drain valve and initial filter element.

Model Capacity1
(scfm)
Connection
ANSI FLG (inches)
Heater
(kW)
Blower
(hp)
Full Load
Amps
Height
(in)
Width
(in)
Depth
(in)
Weight
(lbs)
Desiccant
Weight (lbs)
HRE-600 600 3 FLG 16 5 27 103 93 50 2685 1060
HRE-800 800 3 FLG 24 7.5 40 104 93 50 3580 1420
HRE-1000 1000 3 FLG 27 7.5 44 118 98 52 4475 1710
HRE-1200 1200 4 FLG 37 10 53 119 101 60 5370 2100
HRE-1600 1600 4 FLG 45 10 69 120 115 71 7160 2570
HRE-2000 2000 4 FLG 52 10 77 122 117 73 8950 3620
HRE-2500 2500 6 FLG 64 15 98 122 136 79 10740 4340
HRE-3000 3000 6 FLG 78 15 115 122 138 79 13427 5520
HRE-3500 3500 6 FLG 90 15 130 132 161 82 15665 5820
HRE-4000 4000 6 FLG 100 20 148 140 152 86 17902 6550
HRE-5000 5000 6 FLG 120 20 172 147 174 93 22377 8240
HRE-6000 6000 8 FLG 170 25 215 CF* CF* CF* 26852 CF*
HRE-7000 7000 8 FLG 200 25 275 CF* CF* CF* 31327 CF*
HRE-8000 8000 8 FLG 230 25 295 CF* CF* CF* 35805 CF*
HRE-10000 10000 10 FLG 280 25 340 CF* CF* CF* 44755 CF*
CF*- consult factory

Standard Voltage: 460V/60 Hz/3Ph

1 Capacity based on -40°F pdp, 100 psig operating pressure, 100°F inlet temperature and 100°F ambient temperature according to CAGI ADF 200.