Skip Navigation

Aircel DC Series

Cycling Refrigerated Dryers 38°F Dew Point (1,000 - 4,000 scfm)

ECA Best Choice Icon ECA Plug&Go Icon ECA Factory Direct Pricing Icon ECA Request Quote Icon Air Dryer Live Chat IconDryer Sizing Tool

With the introduction of Aircel's DC Series (1,000 - 4,000 scfm) refrigerated air dryers, the bar has been raised and a new performance standard has been set for cycling dryers. You no longer have to accept dryers with a large heavy footprint, circulating pumps, unpredictability, and uncontrollable dew points as found in typical cycling dryers utilizing 30 year old technology.

From heavy industrial to high technology environments, Aircel's DigiCel offers you the exact air treatment you require. Aircel's DigiCel is a truly energy efficient dryer design that provides the precise dew point control that industrial processes demand.

• 38°F - 50°F Dew Point
• Ambient Air Temperature 35°F - 120°F
• Maximum Inlet Air Temperature 140°F
• Maximum Operating Pressure: 200 psig
• 1 Year Standard Limited Warranty
• Environmentally Friendly Refrigerant R-134a
• SingleCel (1,000-2,000 scfm) & MultiCel (2,500-4,000 scfm)

If you have questions on how to properly select a compressed air dryer, contact our knowledgeable customer service toll-free: 866-650-1937 or send us an email request.

Aircel DC Models Group
Product Selection

Dimensions & Specifications

Search below based on your specific needs and click on a model to order, view pricing, or download product information. If you have questions on how to properly select a compressed air dryer, contact our knowledgeable customer service toll-free: 866-650-1937 or send us an email request.

Model

Capacity
(scfm)*

Connection
Height
(in.)
Width
(in.)
Air-
Cooled
Depth
(in.)
Water-
Cooled
Depth
(in.)
Nominal
Ref.
HP

Air-
Cooled
kW

Water-
Cooled
kW
Weight
(lbs)
DC-1000 1000 3" FLG 60 26 81 55 7 5.1 3.15 1100
DC-1250 1250 3" FLG 60 26 81 55 8.5 5.6 3.51 1450
DC-1600 1600 4" FLG 60 26 81 55 10 7.7 4.80 1700
DC-2000 2000 4" FLG 60 26 81 55 13 10.5 7.23 1900
DC-2500 2500 4" FLG 79 70 81 55 17 11.2 7.02 3400
DC-3200 3200 6" FLG 79 70 81 55 20 15.4 9.60 3900
DC-4000 4000 6" FLG 79 70 81 55 26 21.0 14.47 4300

* 100 psig inlet pressure / 100°F inlet temperature / 100°F ambient temperature / 38°F pressure dew point. Average kW per hour of dryer operation at full capacity.

Notes:
Ambient air temperature: 35°-120°F
Inlet air temperature: 140°F max.
Operating pressure: 200 psig max.
NEMA4 Standard
VC models are standard air-cooled.
Standard Voltage 460-3-60.

Aircel DC Dimensions