CALL NOW: 866.650.1937

Recently added item(s) ×

You have no items in your shopping cart.

Replacement for Atlas Copco 2906-0149-00 Compressor Kit

Replacement for Atlas Copco 2906-0149-00 Compressor Kit

$1,465.59
Part #: 2906-0149-00
$1,465.59
Availability : Contact Us
4000 Hour Maintenance Kit Model ZR5
OR



YOU MAY ALSO NEED

Description

Details

Our 4000 Hour Kit contains all the necessary filters, gaskets, washers, diaphragms and supplementary kits for performing a 4000 hour service on Atlas Copco Compressor Model ZR5. As a value added benefit, our kits also include Mark II element balancing diaphragms, as well as Amot water regulating valve seal kits, both of which are not included by the OEM.

eCompressedair provides quality Atlas Copco equivalent parts that meet or exceed the OEM specifications. Aftermarket parts are more cost effective than brand name parts and can typically allow for a reduction in your annual maintenance costs over the life of the compressor.

Parts List
Qty. Part # Description
1 0650-1000-94 Gasket, Flange
1 0653-1124-00 Washer, Copper
3 1030-0979-00 Element, Air Filter
1 1202-5584-00 Gasket, Flange
1 1613-1268-13 Diaphragm
1 1613-6105-00 Filter, Oil, Spin-On
1 1619-1846-00 Diaphragm, Unloader
1 2253-7856-00 Diaphragm, HP (4 Hole)
1 2253-7858-00 Diaphragm, LP (4 Hole)
1 2906-0133-00 Kit, Seal
1 2910-0179-00 Kit, Oil Pump
2 2910-0206-00 Kit, Moisture Trap
1 2910-3038-00 Kit, Unloader Valve
How it Works

As recommended by the OEM, the following criteria should be considered when performing a 4000 hour preventative maintenance service on this specific compressor:

  • Check unloading and loading pressures
  • Check intercooler pressure
  • Check oil pressure
  • Check aftercooler water outlet temperature
  • Check compressor water outlet temperature
  • Check compressed air outlet temperature
  • Check air intake filter service indicator
  • Check oil level
  • Drain condensate from intercooler and aftercooler drain receivers after stopping
  • Check that condensate is discharged from intercooler and aftercooler drain receivers during loading
  • Drain condensate from pulsation damper of bleed-off pressure safety switch
  • Clean down unit
  • Drain condensate from air receiver, if installed
  • Check for water or oil leaks; Inspect all pipes and tubes, tigthen loose connections
  • Replace damaged gaskets or tubes
  • Replace air intake filter element(s)
  • Clean breather of step-up gear casing