CALL NOW: 866.650.1937

Recently added item(s) ×

You have no items in your shopping cart.

BEKOMAT® Standard Series Drain Valves

BEKOMAT® Standard Series Drain Valves

$0.00
Electronically Controlled, 12 - 232 psi, 100 - 50,000 cfm

Series 13, 14, 16 CO, 31, 32, 33

BEKOMAT® from BEKO has become the industrial standard because of its high reliability and particularly because it offers energy-saving operation without loss of compressed air. There are a number of very good technical reasons for this:

Compared with float drains, BEKOMAT® has decisive advantages, especially since it:

  • •  functions unaffected by dirt, resulting in realiable operation
  • •  is equipped with an alarm signal
  • •  requires very little maintenance
  • •  has large cross-sections to prevent emulsification

BEKOMAT® also has decisive advantages over solenoid valves, especially since it:

  • •  operated in accordance with the actual condensate quanitiy
  • •  avoids unnecessary loss of compressed air
  • •  is equipped with a fault signal
  • •  has large cross-section value to prevent emulsification
Models

Model Specifications

Select by BEKOMAT® model below to see pricing, product information, or to order. Contact our customer service toll-free: 866-650-1937 with any questions on our BEKO Drain Valves or to place an order. How to Select Model

STANDARD BEKOMAT® Model Range

BEKOMAT® 31 BEKOMAT® 32 BEKOMAT® 33* BEKOMAT® 13* BEKOMAT® 14* BEKOMAT® 16 CO
Maximum flow rate (scfm) 100 225 500 1300 5400 50000
Working pressure (psig) min. 12 12 12 12 12 12
Working pressure (psig) max. 232 232 232 232 232 232
Weight (lbs) 1.8 2.2 3.6 4.4 6.4 13.0
Min. / max. temperature °F +34/140 +34/140 +34/140 +34/140 +34/140 +34/140
Connections (inlet) 1 x 1/2" 1 x 1/2" 3 x 1/2" 2 x 1/2" 3 x 3/4" 2 x 3/4 - 1 x 1"
Outlet (hose connector) 1 x 1/4" 1 x 1/4" 1 x 1/2" 1 x 1/2" 1 x 1/2" 1 x 1/2"
Outlet (hose di) 3/8" 3/8" 1/2" 1/2" 1/2" 1/2"
Standard Voltage 115 VAC
50-60 Hz
115 VAC
50-60 Hz
115 VAC
50-60 Hz
115 VAC
50-60 Hz
115 VAC
50-60 Hz
115 VAC
50-60 Hz

* Additional models are available for purchase: 33 CO, 13 CO, and 14 CO. These models are used for oil-contaminated and oil-free units. Contact customer service for more informaton to order these CO models.

AVAILABLE VOLTAGES

No additional charge, must request specific voltage when placing order

Model Number 230 VAC 200 VAC 115 VAC 110 VAC 100 VAC 48 VAC 24 VAC 24 VDC
BEKOMAT 31 ° ° - ° ° - -
BEKOMAT 32 ° ° - ° ° ° °
BEKOMAT 33 ° ° - ° ° ° °
BEKOMAT 12 ° ° - ° ° ° °
BEKOMAT 13 ° ° - ° ° ° °
BEKOMAT 14 ° ° - ° ° ° °
BEKOMAT 16 ° ° - ° ° ° °
BEKOMAT 3 ° ° - ° ° ° °
BEKOMAT 6 ° ° - ° ° ° °
° Optional Voltage
• Standard Voltage
- Not Available
Certain voltage / drain model combinations are not available with NPT thread.
All voltages are operational at either 50 or 60 Hz.

How to Select a Model

To use the BEKOMAT® Product Selector Chart, first locate either your compressor horsepower (for multiple compressors use the total system horsepower) or the net flow rate of your compressed air system. Follow the row to the right and locate the column with the appropriate installation point for your particular application (i.e wet receiver tank) and you will instantly know the correct BEKOMAT® model size for your application and installation point.

For extremely corrosive applications where excessive amounts of rust, scale or particles are present please contact our customer service toll-free: 866-650-1937 for special installation instructions.

Capacity tests and our long-term experience have enabled us to make locational adjustments to our capacity figures by taking global climate data into account. Therefore, if you feel that your regional location may have an impact on the application or installation, please consult our customer service toll-free: 866-650-1937 for details.

Models: BEKOMAT® 31 BEKOMAT® 32 BEKOMAT® 33 BEKOMAT®13 BEKOMAT®14 BEKOMAT®16 CO
COMPRESSOR PERFORMANCE
Compressor HP Compressor SCFM After Cooler Wet Receiver Tank Pre-Filter Refrigerant Dryer After-Filter Dry Receiver Tank
20 90 31 31 31 31 31 31
40 180 32 32 31 31 31 31
50 225 32 32 31 32 31 32
60 270 33 33 31 32 31 32
75 338 33 33 31 32 31 32
100 500 33 33 31 32 31 32
125 563 13 13 21 33 31 32
150 675 13 13 31 33 31 33
175 788 13 13 31 33 31 33
200 900 13 13 31 33 31 33
250 1125 13 13 32 13 32 13
300 1300 13 13 32 13 32 13
400 1800 14 14 32 13 32 13
500 2250 14 14 32 13 32 13
750 3375 14 14 33 14 33 14
1000 5000 14 14 33 14 33 14
1250 5625 16 16 13 14 13 14
1500 6750 16 16 13 14 13 14
1750 7875 16 16 13 14 13 14
2000 9000 16 16 13 14 13 14
2500 11250 16 16 13 16 13 16
3000 13500 16 16 13 16 13 16
4000 18000 16 16 14 16 14 16
5000 22500 16 16 14 16 14 16
Features & Benefits

KEY FEATURES: BEKOMAT®

  • UL/CSA approved devices including cable and plug
  • integrated, service-free strainer
  • highest reliability guaranteed
  • true zero air loss, fully automatic on demand drainage
  • 26 different models for all applications
  • integrated alarm function with dry contact for remote monitoring
  • lowest maintenance - 1,000,000 cycles guaranteed

TRUE ZERO AIR LOSS
Maximum energy savings

HIGHEST RELIABILITY
Unaffected by dirt

LOWEST MAINTENANCE
Reduce overall time and costs

SENSOR CONTROLLED
Safe for all condensate types

FULLY AUTOMATIC
Monitors level and function

STANDARD BEKOMAT®

BEKOMAT® 13, 14, 16, 31, 32 AND 33

Compressor
Around 60 percent of the total condensate is produced in the aftercooler of the compressor.

Receiver
More than 10 percent of the total condensate stems from the air receiver.

Dryer
Up to 25 percent of the total condensate seperates from the vapor in the refrigeration dryer. Therefore, efficient drying requires equally efficient condensate drainage.

Filter
What is the use of a perfect filter if the condensate drain is not matched to the task or not functioning correctly? Our standard BEKOMAT® series of drains are perfectly suitable and have design elements specifically for compressed air filters.

How it Works

BEKOMAT How it Works

Empty state:

Condensate trickles through the inlet opening and collects in the container 2. The diaphragm valve is closed, since the pilot supply line 3 and the solenoid valve 4 ensure pressure compensation above the valve diaphragm 5. The larger surface area above the diaphragm results in a high closing force, so that the valve seat is tight and leak proof.

Filled state:

When the container 2 has filled with condensate and the capacitive level sensor 6 signals at the maximum point, the solenoid valve is energized and the area above thevalve diaphragm is vented. The valve diaphragm lifts off the valve seat, 7 and the pressure in the housing forces the condensate into the discharge pipe 8.

The BEKOMAT® electronic system now calculates the discharge rate down to the minimum point and uses this figure to determine the exact valve opening period required. The valve will again be fully closed and leak proof before any compressed air can escape.

Should the condensate discharge fail to function properly blocked discharge pipe, faulty diaphragm, the device will change to the alarm mode after 60 seconds. In this case, the red LED flashes and, if desired, the alarm signal is relayed via a potential-free contact. While in the alarm mode, the solenoid valve will open every 4 minutes for a period of 7.5 seconds. This ensures that a BEKOMAT®unit filled in an unpressurized state will, under pressure, automatically revert to normal operating conditions and thus clear the alarm.

From the BEKOMAT® the condensate can flow for treatment into the QWIK-PURE® or ÖWAMAT® oil-water separator which is designed to deal with condensate contaminated with free and dispersed non-emulsified or emulsified (QWIK-PURE® only) oil. In the case of stable emulsions, our BEKOSPLIT® emulsion splitting plant will clean up the condensate leaving only a minimum of waste for disposal. Either system will help your company to conform to the legal requirements concerning the treatment and discharge of compressed air condensate.

 

3D Drawing

BEKOMAT® 31, 32 AND 33
The BEKOMAT® 31, 32 and 33 offer significant enhancements to proven solutions.

Even more reliable, with fast and problem free installation. Maintenance that used to take hours, now takes only seconds.

BEKO achieves these targets through a construction that has never been realized until now, and consists of only two units joined by a simple, snap-fit connection.

BEKOMAT® FOR ALL OPERATING CONDITIONS
A wide range of BEKOMAT® models makes it possible to select a suitable and cost-effective device for each particular application.

The device can be adapted to all the usual supply voltages; the operating elements and the control system are protected to IP 65.

BEKOMAT 3D 31-32-33

BEKOMAT 3D 31-32-33 2nd

 

 

Dimensions

BEKOMAT Dimensions

 

 

Replacement Parts

eCompressedair offers replacement parts for the BEKOMAT drain valves. Annual service parts are available online to purchase below, or for other replacement parts and kits not listed below for the BEKOMAT, contact our customer service team by calling toll-free 866-650-1937 or email sales@ecompressedair.com for pricing and information.

Annual Service Parts

BEKOMAT® 31 Service Units for Standard Series

BEKOMAT® 32 Service Units for Standard Series

BEKOMAT® 33 Service Units for Standard Series

BEKOMAT® 13 Wearing Parts Kits for Standard Series

BEKOMAT® 14 Wearing Parts Kits for Standard Series

BEKOMAT® 16 CO Wearing Parts Kits for Standard Series

BEKOMAT® 12 CO PN63 Wearing Parts Kits for High Pressure Series

BEKOMAT® 13 CO PN50 Wearing Parts Kits for High Pressure Series

BEKOMAT® 14 CO PN25 Wearing Parts Kits for High Pressure Series

BEKOMAT® 13 CV Wearing Parts Kits for CV Series

BEKOMAT® 14 CV Wearing Parts Kits for CV Series

BEKOMAT® 16 CO CV Wearing Parts Kits for CV Series