Combo Diaphragm Drain Valves

Combo Diaphragm Drain Valves

$0.00
Timer Controlled, 0 - 300 psi, unlimited cfm

The Combo Diaphragm has a large orifice which virtually eliminates clogging by rust, scale, or other air system debris. The diaphragm's functionality is to lift up to expose a large orifice. If the bleed orifice in the diaphragm clogs, then the diaphragm will not lift up, the valve is seemed blocked, and stays closed.

The Combo Diaphragm is designed to remove condensate from compressors, compressed air dryers and receivers regardless of their size or capacity - simply adjust the interval and discharge times to suit the particular compressed air system.

Benefits:

  • • Compressed air systems up to any size
  • • The direct acting valve is serviceable
  • • Suitable for all types of compressors
  • • TEST (micro-switch) feature
  • • 2 year warranty

Advantages:

  • • Discharge up to 2 gallons per drain opening at 100 psig
  • • Large (7/16") valve orifice
  • • Medium pressure up to 300 psi
Models

The Combo Diaphragm is available in multiple connection sizes and voltage options. Select the part number below for the option needed to order online or see more information. If you have questions contact our customer service by calling toll-free: 866-650-1937 or email sales@ecompressedair.com.

Model
Number
Inlet Conn.
Size
Voltage Min/Max
Pressure
Valve Body Valve Min/Max
Temperature
Max Compressor
Capacity
Time Cycle Range
(ON/OFF)
Diaphragm Valve
Orifice Size
3001 1/4" 230 VAC 0 - 300 psi Brass 4°F/130°F unlimited 0.5/10 sec - 0.5/45 min 7/16"
3021 1/4" 115 VAC 0 - 300 psi Brass 4°F/130°F unlimited 0.5/10 sec - 0.5/45 min 7/16"
3061 1/4" 24 VAC 0 - 300 psi Brass 4°F/130°F unlimited 0.5/10 sec - 0.5/45 min 7/16"
3081 1/4" 24 VDC 0 - 300 psi Brass 4°F/130°F unlimited 0.5/10 sec - 0.5/45 min 7/16"
3091 1/4" 12 VDC 0 - 300 psi Brass 4°F/130°F unlimited 0.5/10 sec - 0.5/45 min 7/16"
3002 3/8" 230 VAC 0 - 300 psi Brass 4°F/130°F unlimited 0.5/10 sec - 0.5/45 min 7/16"
3022 3/8" 115 VAC 0 - 300 psi Brass 4°F/130°F unlimited 0.5/10 sec - 0.5/45 min 7/16"
3062 3/8" 24 VAC 0 - 300 psi Brass 4°F/130°F unlimited 0.5/10 sec - 0.5/45 min 7/16"
3082 3/8" 24 VDC 0 - 300 psi Brass 4°F/130°F unlimited 0.5/10 sec - 0.5/45 min 7/16"
3092 3/8" 12 VDC 0 - 300 psi Brass 4°F/130°F unlimited 0.5/10 sec - 0.5/45 min 7/16"
3003 1/2" 230 VAC 0 - 300 psi Brass 4°F/130°F unlimited 0.5/10 sec - 0.5/45 min 7/16"
3023 1/2" 115 VAC 0 - 300 psi Brass 4°F/130°F unlimited 0.5/10 sec - 0.5/45 min 7/16"
3063 1/2" 24 VAC 0 - 300 psi Brass 4°F/130°F unlimited 0.5/10 sec - 0.5/45 min 7/16"
3083 1/2" 24 VDC 0 - 300 psi Brass 4°F/130°F unlimited 0.5/10 sec - 0.5/45 min 7/16"
3093 1/2" 12 VDC 0 - 300 psi Brass 4°F/130°F unlimited 0.5/10 sec - 0.5/45 min 7/16"

Common Installation:

The Combo Diaphragm is designed to remove condensate from compressors, compressed air dryers, and receivers up to any size, type or manufacturer.

Combo Diaphragm Installation

Specifications

Product Specification

  • Maximum compressor system capacity: Unlimited
  • Valve connection: 1/4", 3/8", & 1/2" NPT
  • Minimum system pressure: 1.5 PSI
  • Maximum system pressure: 300 PSI
  • Minimum medium temperature: 4°F
  • Maximum medium temperature: 130°F
  • Valve orifice: 7/16"
  • Type of operating valve: Diaphragm
  • Valve seals: FPM (Viton)
  • Installation enclosure: P65/NEMA 4
  • Voltage: 10 to 380 VAC/DC 50/60 Hz
  • Time cycle range (ON - OFF): 0.5/10 seconds - 0.5/45 minutes
Diagram

The forged brass valve body has a full port 7/16" drain orifice. This large orifice virtually eliminates clogging by rust, scale, or other air system debris and can discharge more than two gallons of condensate per drain opening at 100 psig. It is recommended the use of a strainer in front of any diaphragm valve. The valve does have a large orifice, but the diaphragm needs to be protected.

Product Dimensions

Combo Diaphragm Product Drawing

Diaphragm

This is a diaphragm and its function is to lift up to expose a large orifice. If the bleed orifice in the diaphragm clogs then the diaphragm will not lift up, the valve is deemed blocked, and stays closed.

Combo Diaphragm Drawing