Skip Navigation

BEKO Oil/Water Separators

QWIK-PURE® Series, Cartridge Media, 45 - 7,200 SCFM

Beko Qwik-Pure-Group-OverviewNon-treatment of compressed air condensate leads to high legal and financial risks, and as off-site disposal costs continue to increase your profits will continue to decrease. Furthermore, traditional, gravity type oil-water separators lack the ability to adapt both to new lubricants and new growth, while often times requiring time consuming adjustments from staff that is usually unavailable.

BEKO has been at the forefront of oil-water separation and condensate processing technology for more than two decades. Through intense research and development, and consistent upgrades and improvements over time, our devices have become the standard of the industrial sector. Often copied, but never duplicated.

 

 


Models

Model Specifications

Select by QWIK-PURE® model below to see pricing, product information, or to order. Contact our customer service toll-free: 866-650-1937 with any questions on our BEKO Oil/Water separators or to place an order.

QWIK-PURE 25 QWIK-PURE 50 QWIK-PURE 100 QWIK-PURE 200 QWIK-PURE 350
Tank capacity
(container volume)
2.64 gal 4.91 gal 17.73 gal 30.51 gal 60.34 gal
Filling capacity 1.14 gal 3.09 gal 12.46 gal 19.15 gal 36.24 gal
Condensate inlet
(hose connection)
2 x ½"
(di =10 mm)
2 x ½"
(di = 10 mm)
½"
(di =13 mm)
or 1"
(di = 25 mm)
3 x ½"
(di =13 mm)
1 x 1"
(di = 25 mm)
3 x ½"
(di = 13 mm)
1 x 1"
(di = 25 mm)
Water outlet
(hose connection)
1 x ½"
(di =10 mm)
1 x ½"
(di = 10 mm)
1 x 1"
(di = 25 mm)
1 x 1"
(di = 25 mm)
1 x 1"
(di = 25 mm)
Weight empty 7.7 lbs 12.7 lbs 24.5 lbs 70.6 lbs 92.6 lbs
Min /max
temperature
+41 to +140 °F +41 to +140 °F +41 to +140 °F +41 to +140 °F +41 to +140 °F
Max operating
pressure at inlet
232 psig 232 psig 232 psig 232 psig 232 psig
Pre-filter capacity 0.66 gal 1.24 gal - 4.89 gal 9.60 gal
Main filter capacity 0.69 gal 1.27 gal 10.65 gal 5.42 gal 10.65 gal
Replacement
Cartridge Set
QWIK-PURE 25 QWIK-PURE 50 QWIK-PURE 100 QWIK-PURE 200 QWIK-PURE 350

How to Select a Model

To use the QWIK-PURE® Product Selector Chart, first locate either your compressor horsepower (for multiple compressors use the total system horsepower) or the net flow rate of your compressed air system. Follow the row to the right and locate the column with the appropriate compressor type and lubricant for your particular application (i.e piston compressor with synthetic lubricant) and you will instantly know the correct QWIK-PURE® model size for your compressor type.

The cartridge lifetime is typically 6 months or 3,000 operating hours depending on type of compressor employed, compressor lubricant, compressor load, ambient temperature, compressed air temperature and other various conditions.

Models: QWIK-PURE 25 QWIK-PURE 50 QWIK-PURE 100 QWIK-PURE 200 QWIK-PURE 350
COMPRESSOR PERFORMANCE PISTON COMPRESSOR ROTARY SCREW COMPRESSOR
Compressor HP Compressor SCFM Mineral Oils Synthetic Oils Mineral Oils PAO/Diester Oils Polyglycol/Synthetic
10 45 25 25 25 25 25
15 60 25 25 25 25 25
20 90 25 50 25 25 50
25 113 50 50 25 50 50
35 158 50 100 50 50 100
40 180 50 100 50 50 100
50 225 100 100 50 100 100
60 270 100 200 100 100 200
75 338 100 200 100 100 200
100 450 200 350 100 200 200
110 495 200 350 200 200 350
130 585 200 200 350 350
175 788 350 350 350 350
200 900 350 350 350 2 x 200
210 945 350 350 350 2 x 350
250 1125 350 350 350 2 x 350
270 1215 350 2 x 350 2 x 350
350 1575 350 2 x 350 2 x 350
400 1800 2 x 200 2 x 350 3 x 350
500 2250 2 x 350 2 x 350 3 x 350
600 2700 2 x 350 3 x 350 4 x 350
700 3150 2 x 350 3 x 350 4 x 350
800 3600 2 x 350 4 x 350 4 x 350
1000 4500 2 x 350 4 x 350
1300 5850 4 x 350 4 x 350
1600 7200 4 x 350