Details
A compressor running in a "start-stop" mode operates more
efficiently if the pressure trapped in the compressor head and
discharge line is released after each pump-up cycle. This allows
smoother starts and the use of a motor with lower starting
torque.
The most convenient way to release this trapped pressure is to
use a Load Genie® combination check and unloader valve, available
only from Control Devices, Inc. Simply install this unique valve in
the compressor discharge line, and the Load Genie® does the
rest!
The Load Genie® senses air flow when the compressor is running
and closes an unloading orifice port. When airflow stops (such as
when the pressure switch turns off the motor), the Load Genie®
opens the unloading orifice to release head pressure, and the
built-in check valve keeps receiver air from leaking back into the
discharge line and compressor head.
Alternative methods rely on external unloading valves mounted on
the pressure switch or compressor. These external unloading valves
are connected with appropriate tubing and fittings to the
compressor discharge line or compressor head. A tank check valve is
also required. These systems, then consist of the unloading valve,
connecting tubing with appropriate fittings, a tank check valve,
and the labour to install it all.
Compare this to the single component installation of a Load Genie®
and the advantages are apparent.
Model
Name |
Inlet
Size |
Outlet
Size |
Min & Max Flow
SCFM |
Lenght
(mm) |
Hex (mm) |
CA24 |
3/4" O.D. tube compression |
1/2" MPT |
8-24 |
54.0" |
25.4" |