Fox Model FT2 Inline Flowmeter 2" 316 SS Body 24 VDC

Fox Model FT2 Inline Flowmeter 2" 316 SS Body 24 VDC

$3,641.00
Part #: 1234051
$3,641.00
Availability : Contact Us
Model FT2-20P-SS-ST-E1-DD-B0-G1



YOU MAY ALSO NEED

Description

Details

Fox Model FT2 Inline 2" Flowmeter

FT2-20P-SS-ST-E1-DD-B0-G1

Parent Model No: FT2 - Inline Mass Flowmeter & temperature transmitter
Feature 1 Probe/Body: 20P - 2 inch 316ss flow body with male npt ends (schedule 40)
Feature 2 Sensor Material: SS - 316 stainless steel sensor and flowbody
Feature 3 Sensor Type: ST - Standard Sensor -40 to 250F (-40 to 121C)
Feature 4 Enclosure: E1 - Local NEMA 4X enclosure, 24 VDC powered
Feature 5 Display & Config. Panel: DD - No Display & Configuration Panel
Feature 6 Bus Options: B0 -  No communication bus
Feature 7 Calibration: G1 - Air, N2: MF less than 1200 SCFM (2040 NM3H)

Need Additional Options?
Download Fox Flowmeter Component Sheet

 

Fox FT2 Gas Mass Flowmeter & Temperature Transmitter

  • Measures gas flow rate in SCFM, NM3/hr, Lbs/hr, Kg/hr, & many more
  • Wide measurement range; 100 to 1 turndown typical
  • Measures process gas temperature
  • 4 to 20 mA for flow rate & temperature; pulse output for flow/total
  • RS232 for connecting a Palm Handheld or computer; RS422/RS485-Modbus, Profibus-DP, DeviceNet or Ethernet Welded, 316 SS sensor construction; Hastelloy C276 optional
  • Microprocessor based, field programmable electronics
  • On-board 2 line x 16 character, backlit display with configuration panel to view/set readings and parameters
  • Palm Handheld Terminal available to view/set readings and parameters
  • NIST traceable calibration
  • Low-end sensitivity for leak detection
  • Negligible pressure drop
  • No moving parts design
  • FM (U.S.) & FMc (CANADIAN) approved for Class I, II, III, Division 2, Groups A, B, C, D, E, F, G T4A hazardous locations. NEMA 4X and CE approved.

Need Additional Information?
Download Fox Flowmeter Technical Guide


Specifications

Download Fox Flowmeter Technical Guide

Performance Specs

Flow Accuracy:

± 1% of reading ± 0.2 % of full scale*
* Point velocity for insertion flowmeters. Fox recommends a minimum of 15 diameters of straight pipe upstream of the flowmeter and 10 diameters downstream for insertion flowmeters. Fox recommends a minimum of 8 diameters of straight pipe upstream of the flowmeter and 4 diameters downstream for inline flowmeters.

Flow Repeatability:
± 0.2% of full scale

Flow Response Time:
0.9 seconds (one time constant)

Temperature Accuracy:
± 1.8° F (± 1.0° C) over -40 to 250° F (-40 to 121° C); ± 3.6° F (± 2.0° C) over 250 to 650° F (121 to 343° C). Minimum velocity 60 SFPM.a

 


 

Operating Specs

Units of Measurement:

SCFM, SCFH, NM3/hr, NM3/min, Kg/hr, Kg/min, Kg/sec, Lbs/d, Lbs/hr, Lbs/min, Lbs/sec, NLPH, NLPM, SLPM, SMPS, NMPS, SFPM, MMSCFD

Full Scale Flow Ranges for In-Line Flowmeters:

Size SCFM NM3/hr
0.25" 0-16 0-27
0.5" 0-48 0-82
.75" 0-120 0-204
1" 0-192 0-326
1.25" 0-332 0-564
1.5" 0-450 0-760
2" 0-750 0-1280
2.5" 0-1090 0-1855
3" 0-1600 0-2720
4" 0-2880 0-4893
6" 0-6400 0-10870

Gas Pressure (maximum):
In-Line (1/4" through 6"):
NPT 500 psig (34.5 barg)
150# flange 230 psig (16 barg)
Check with factory for higher pressure options

Inline Flowmeter:
Note: Pressure ratings stated for temperature of 100°F (38°C).

Temperature:
Std sensor: -40 to 250°F (-40 to 121°C)
HS Sensor: 32 to 400°F (0 to 204°C)
HT Sensor: 32 to 650°F (0 to 343°C)
Enclosure: -40 to 158°F (-40 to 70°C) without display, 32 to 140°F, (0 to 60°C) with display

Input Power:
24 VDC, ± 10%, 0.75 amp standard;
85 to 250VAC 50/60Hz, 20 watts optional

Output:
Two isolated 4 to 20 mA outputs (1 for flow & 1 for temperature); isolated pulse output 0 to 100Hz, 10 volts p/p for flow (the pulse output can be used as an isolated solid state output for alarms)
RS232 for connecting a Palm Handheld or computer; RS422/ RS485-Modbus, Profibus-DP, DeviceNet or Ethernet

 


 

Physical Specs

Sensor material:

316 stainless steel standard; Hastelloy C276 optional
Enclosure: FM (U.S.) & FMc (CANADIAN) approved for Class I, II, III, Division 2, Groups A, B, C, D, E, F, G, T4A hazardous locations. NEMA 4X and CE approved.
Options: Remote NEMA 4X electronics enclosure with explosion-proof sensor j-box.

Cabling:
Remote enclosure: 5-conductor, 18 AWG, twisted, shielded, 100 feet maximum
Packing gland assembly: 125 psig (8.6 barg ) max. (See Figure 6)
High pressure (crank) retractor: NPT 600 psig (41.4 barg), ANSI 150 flange & ANSI 300 flange, no valve supplied. (See Figure 7)

 


 

Dimensional

Inline Flowmeter Dimensions - See Diagrams 3 & 5
Pipe Size L H HH
0.25" 5.80 (14.7) 12.5 (31.8) 9.9 (25.1)
0.5" 12.0 (30.5) 12.5 (31.8) 9.9 (25.1)
.75" 12.0 (30.5) 12.5 (31.8) 9.9 (25.1)
1" 15.0 (38.1) 12.5 (31.8) 9.9 (25.1)
1.25" 12.0 (30.5) 12.5 (31.8) 9.9 (25.1)
1.5" 12.0 (30.5) 12.5 (31.8) 9.9 (25.1)
2" 12.0 (30.5) 12.5 (31.8) 10.0 (25.1)
2.5" 18.0 (45.7) 12.6 (32.0) 10.0 (25.4)
3" 18.0 (45.7) 12.6 (32.0) 10.0 (25.4)
4" 18.0 (45.7) 12.6 (33.3) 10.0 (26.7)
6" 24.0 (61.0) 14.2 (36.1) 11.6 (29.5)

Note: Dimensions in parenthesis are centimeters. For certified drawings,
consult factory.

Download Fox Flowmeter Technical Guide

 